Rotech’s Guide to Selecting a Boom Gate
Our boom gate comparison table aims to assist you in making an informed choice that aligns with your access control requirements. Each product has its own set of distinct features designed to cater to a wide range of needs, from residential and commercial carpark use to heavy-duty industrial applications.
Selecting the right boom gate requires careful consideration of many factors, including application, traffic flow, site dimensions, safety, and environmental conditions. That’s why Rotech offers a wide variety of high-quality automatic, manual, commercial, and industrial-grade boom gates, engineered for performance and built to last. Whether you need an affordable solution for low-volume traffic or robust access control for a busy industrial site, we have the perfect boom gate to suit your application.
Rotech Automation offers an extensive range of high-quality automatic and manual security boom gates, to fit any configuration:
Innovative, Intensive use, durable low maintenance cost automatic boom gates: Brushless Motor technology brings durability and affordability without compromising on quality, new design features include cabinet and pole LED lighting for enhanced security.
Compact automatic boom gate: Ideal for tight spaces, this narrower cabinet design fits where others can’t, like in an underground carpark with narrow curbs or low ceilings.
3 to 8-metre intensive-use boom gates: Our range suits most applications, offering 100% duty cycle, precise speed control, and high-quality European Standards Safety.
Solar-powered automatic boom gates: Still offering similar performance, high-speed and 100% duty cycle but powered on a tailored Solar kit for those remote configurations without access to main power.
Heavy-duty industrial boom gates: Our 10 and 12-metre gates are robust and feature-rich, designed for wide entrances and long-lasting industrial use.
Easy-to-use manual boom gate: Durable with an innovative spring balance and simple locking, perfect for areas without power and low-use sites.
Rotech Boom Gate Comparison Table
To simplify selecting which boom gate will do the job, use the checklist below to identify site requirements, then identify which boom gate from the table below best matches these criteria.
Model | Bionik BK | Bionik AG 3-6M | Bionik AG 8M | EVA 3-5M | EVA 7-8M | Sector SW2 | Access XXL 10M | Koloss 12M |
Boom Pole Length | 3 and 4M | 3-4-6M | 7 and 8M | 3,4,5M | 6,7,8M | 1.5M, 4.5M, 6M | 10M | 12M |
Opening Time | 2 to 6 sec or 3 to 6 sec | 3 to 6 sec and 4 to 8 sec | 9 to 29 sec | 3 to 6 sec | 3.5 to 6 sec | 3, 3, 6 sec | 8 sec | 9 to 12 sec |
Duty Cycle | 5000/day | 5000/day | 2500/day | Intensive Use | Intensive Use | Max 3000/day | 100% Duty Cycle | 75 cycle/hour |
Accessory Power Supply | 24 vdc | 24 vdc | 24 vdc | 24 vdc | 24 vdc | 12vdc | 24 vdc | 24 vdc |
Input Voltage | 230V AC | 230V DC | 230V DC | 240V AC | 240V AC | 240V AC | 85-265V AC | 230V DC |
Motor Power | 200W | 200W | 300W | 205W | 285W | na | MHTM | na |
Manual Release | Y | Y | Y | Y | Y | Y | Y | Y |
Housing Protection Rating | IP54 | IP54 | IP54 | IP44 | IP44 | IP54 | IP54 | IP44 |
LED Light on Cabinet | Y | Y | Y | Y | Y | N | N | N |
Casing Stainless Steel Option | Y | Y | Y | N | N | Stainless Steel | N | N |
Dimensions (HxDxW) in mm | 1203x210x280 | 1237x380x270 | 1237x380x270 | 1200x235x230 | 1265x260x275 | 1167x285x304 | 435x360x1164 | 1240x710x755 |
Battery Back Up | Optional | Optional | Optional | Included | Included | Optional | N | N |
Brushless Y/N | Y | Y | Y | N | N | N | MHTM | N |
Considerations when Selecting Boom Gate
It is important to consider your site’s unique requirements, such as the width of the road to determine the boom arm length, the usage frequency and in which weather conditions and environment the barrier will be located. Check the control access and safety device requirements and compatibility. It’s also important to consider the ease of installation, user-friendly settings and controls and if needed, the solar power and battery backup capabilities for continuity of operation and enhanced energy efficiency.
Evaluate your site requirements:
Intended Use: In high-traffic areas opt for durable, fast-acting gates with vehicle detection and automation. Low-traffic areas can use simpler, manual gates. For high-security zones, integrate gates with RFID, biometrics, and cameras. Moderate security needs may be met with standard gates and basic access control.
Traffic Flow and Volume: Estimate the daily number of operations. Fast-opening, high-duty cycle gates are essential for high traffic to reduce delays while slower-opening speed gates suit low traffic. Consider peak times to ensure efficient handling of fluctuations.
Location and Operating Environment: Ensure the site has adequate power. Our boom gates offer battery backup, fast operation, and solar compatibility. Ensure enough space for the boom arm to move up and down without obstruction. Use weather-resistant materials for harsh conditions to ensure reliable operation.
Size: We have boom gates with different dimensions and pole lengths to fit your needs. Our boom arms range from 3 to 8 meters, with options up to 12 meters for larger roads, ideal for mine sites tunnel access and rail crossings. Compact designs are also available for tight spaces like underground carparks.
If you can’t decide or see an option matching your requirements, contact our team today. We are happy to assist you select the right boom gate solution to suit your needs.