The signal of each individual channel is adjusted automatically, which compensates for misalignment and contamination during operation, The transmitter and receiver units are optically synchronised.
The advanced automatic signal-tracking (AST) feature ensures that no onsite set-up or adjustments are required.
Both the transmitter and receiver detectors are protected against reverse polarity of power supplies, control input and output signals. The output is also protected against short circuit and inductive loads.
SafePass SG19 Safety Light Curtain features include:
- 1-10 metre sensing range
- 40 parallel scanning beams
- Active height of 1800 mm
- Detector length of 1930 mm
- Plug connection
- Automatic sensitivity adjustment
- Compact aluminium IP67 housing
- Power, output and system status indicators
- 12-30 V dc supply voltage
- 5 wire solid state relay output
- Test input
- Dynamic sequential blanking function ignores the moving door
For more information download our product datasheet.
SafePass SG19 Safety Beams |
SG19TX Transmitter |
SG19RX Reciever |
Voltage 12-30 Vdc |
12-30 Vdc |
Current consumption |
70 mA (RMS) |
30 mA |
Max output load Solid state |
– |
100 mA |
Short circuit protected |
– |
Yes |
Inductive load protection |
– |
Yes |
Reverse polarity protected |
Yes |
Number of parallel beams |
40 |
Active height |
1800 |
Sensor spacing |
45 mm |
Response time |
– |
50 ms |
Maximum sequential blanking speed |
0,9 m/s |
Minimum size of detectable objects |
50 mm |
Power on indicator |
Green LED |
Output indicator |
– |
Yellow LED |
System status indicator |
– |
Red LED |
Opening angle |
– |
+/– 10° |
Emission angle |
+/– 10° |
– |
Housing dimensions (w x d) G-profile |
19,5 mm x 20,8 mm |
|
Housing material Profile | Lens Cover |
Aluminium (black anodised) Polycarbonate |
Connection |
10m Cable and M12 Plug |
10m cable and M12 Plug |
Light immunity @ 5o incidence |
– |
100 000 lux |
Temperature operation |
+20 to 65 oC |
Sealing class |
IP 67 |
Housing length |
1948 mm |
Active height |
1800 mm |
Connection Output |
– |
Solid State Relay (NC) |
For more information download our product datasheet.
For information about installation and operating instructions please download our PDF